Turbine Flow Meter Installation Guidelines

In general, downstream straight run requirements for turbine flow meters are around 5-10x the piping diameter. The vanes are located (fig. Our hot water turbine meters are available in sizes from 3/4" to 6", with larger sizes available upon request. This velocity is determined by Head pressure. If you have not purchased all of the options, there will be references in this manual which are not applicable to your meter(s). If the computer display is upside down, remove the four screws, turn the display 180 degrees and reinstall the screws. It was designed to withstand rigorous flow measurement applications in the secondary oil recovery market and beyond. Series BF meters with EZ-IN connections offer the accuracy, rugged construction, and maintenance-free operation of conventional NUFLO flow meters plus the following advantages: Lower installation cost. Install two or more meters in parallel if the flow rate is too great for one Meter. Insertion Turbine Flow Meter Installation & Adjustment Guide 2161 Logan St. View online or download Onicon F-1200 Series Owner's Manual. Turbine meters work great on thin, non viscous fluids. The initial verification and calibration are carried out at the factory on an VSL approved calibration bench. In addition, considering the compressibility of the. Turbine flowmeter is a common type of flow meter. Engineering Design LACT & P/L Measurement 5. Consult factory for SAE brass meter requirements. Installation of Turbine flowmeter: First check the flow meter is free from foreign materials and the turbine should rotate freely. ) Bore is the smallest diameter of an orifi ce or nozzle Up = Upstream Diameters Down = Downstream Diameters. Dual counter-rotating axial turbine elements, each with its own rotational sensing system, and an averaging circuit to reduce measurement errors due to swirl and flow profile distortion. Body materials PVC, carbon steel, and stainless steel. Meters may be large diaphragm (600-1000 class), rotary or turbine meters (with or without electronic instruments). Accurate, Reliable Turbine Water Meters for High Volume Measurement Up to 12 inch size in stock. If low unit price is desirable without sacrificing accuracy, then single-use turbine type sensors are a good option particularly if working fluid is low viscosity. turbine flowmeter is the perfect solution to measuring the flow of water and low viscosity liquids. Dwyer meters and totalizers display flow rate. Carlon offers temperature ratings for its hot water turbine meters at 248ºF. OPERATING ABOVE/BELOW THE RANGE OF THE METER. They can be purchased relatively easily from a host of manufacturers and have a manageable pressure drop which is not too detrimental to oil system performance. INTRODUCTION Field testing of gas turbine compressor packages is becoming increasingly frequent because economic pressures demand that an 19 installation's efficiency, capacity, head, power, and fuel flow be. The flow-meter may be installed in any orientation (vertical, horizontal, etc. HP Turbine Field Testing Guide 1 1 Introduction This chapter provides general information on field testing, testing methods, and flow tests for the High Performance Turbine Meter (subsequently referred as HP Turbine meter). Tighten the turbine onto the fit-tings. Turbines, Inc. The meter translates pulse data from the turbine into calibrated flow units shown on the meter’s readout. Dedicated gas flow meter for for oil and gas recycle system 3. These reliable meters offer a pulse output that is linear to the flow rate. 1-2 HP TURBINE INSTALLATION AND MAINTENANCE GUIDE i SIDE VIEW TOP VIEW STRAINER GATE VALUE BYPASS TESTING TEE TURBINE METER Figure 1. With 40+ years of exemplary experience, knowledge, and industry leading support, Pumps and Instrumentation is the largest distributor and # 1 source to buy of Signet products. Flow Measurement Devices Increasing utilization and the value of water makes the understanding of water measuring techniques important and necessary. The importance of understanding the cause of problems and taking appropriate measures. If low unit price is desirable without sacrificing accuracy, then single-use turbine type sensors are a good option particularly if working fluid is low viscosity. The nacelle tilt and roll movements when the turbine is in operation, affect the lidar measurement height. Swirl or non-uniform velocity profiles, such as jetting, at the turbine meter inlet can cause undesirable accuracy performance changes. The flow direction arrow can be found on the side of the flow meter. They can be purchased relatively easily from a host of manufacturers and have a manageable pressure drop which is not too detrimental to oil system performance. KAIFENG WATER LARGE FLOW MEASUREMENT SCIENCE & TECHNOLOGY CO. The nozzle guide vanes are of an aerofoil shape with the passage between adjacent vanes forming a convergent duct. • Install seals on the meter to reduce tampering and indicate when tampering does occur. 5-8) in the turbine casing in a manner that allows for expansion. TB Turbine Flow Meter Instructions The TB are bronze-bodied turbine meters designed for use in pipe sizes 1" to 4". If your meter is a combination of two sizes (like 5/8 x 3/4) use the chart for the smaller size. Distance given here are minimum requirements; double them for desired straight pipe lengths. Turbine flow meters FAQs. The following methods must be perceived when installing the turbine flow meter and operating it after installation. The Sensus WP-Dynamic water meter is NMI pattern approved in Australia for inclusion in non-urban water installations. Operating under the same principle as a Rotary meter, the Turbine Meter is utilized when flow rates are very high. They offer a wide flow and application rangeability. The PanaFlow Z3 joins a portfolio of new. 2 x Qmax Qn Max Continuous Flow + 2% Qt Transitional Flow + 2% Qmin Minimum Flow + 5%. It is recommended that there be a length of straight pipe either side of the turbine of ten times the pipe diameter. The DF25 uses the well-established Differential Pressure (DP) measurement method. The Designed for easy field service of a damaged flow meter Model 1100 repair kits replace only the internal parts, rather than replacing the entire flow meter. Because of the very compact design, the very wide measuring range and the convincing precision of measurements, almost unlimited applications are possible. The general guidelines suggested by manufacturers of turbine flow meters are 15-20 straight pipe diameters (inclusive of the strainer) straight pipe runs upstream and 5 straight pipe diameters straight pipe runs downstream. Upp, Flow Measurement Consultant. Tactical Flow Meter Online Store for Thermal Mass Flow Meters for compressed air and gases, Methane Flow Meters, Natural Gas Flow Meters, MAG meters (Magnetic flow meters), Vortex Flow Meters, Vortex Steam Meters, Multivariable Vortex Flow Meters, Coriolis Mass Flow Meters and Ultrasonic flow meters. Piping connections:Flanged, Victaulic, Dresser, Sanitary, Flangeless (wafer style) Note 4. turbine, including the serial number is etched on the meter body. The Z3 comes fully assembled from the factory and only needs to be bolted into place. Read McCrometer's Company Profile Here. This battery (as supplied standard) acts as the primary power for the unit unless DC power or loop power is connected when it then serves as a battery backup for DC/loop power loss. We have the UK’s largest fleet of flow meters to hire. The nacelle tilt and roll movements when the turbine is in operation, affect the lidar measurement height. Turbine flow meter use a free-spinning turbine wheel to measure fluid velocity, much like a miniature windmill installed in the flow stream. Turbine meters work great on thin, non viscous fluids. They can be purchased relatively easily from a host of manufacturers and have a manageable pressure drop which is not too detrimental to oil system performance. Typical manufacturer specifications for turbine meters call for straight-pipe lengths of 10-15 pipe diameters upstream and five diameters downstream. The gas turbine contains an 18-stage. Turbine Meter Repair Kits are also available, see Appendix B. Dresser meters and instruments products include a comprehensive range of rotary, turbine, and diaphragm meters, metering instrumentation, and test equipment for the global natural gas distribution and transmission industry. Dual counter-rotating axial turbine elements, each with its own rotational sensing system, and an averaging circuit to reduce measurement errors due to swirl and flow profile distortion. Hays Fluid Controls has been manufacturing quality flow meters for years. Flow rate; Density; Before starting a meter proving, let the liquid flow through the meter and prover long enough so that the conditions stabilize. The ProPulse is an excellent choice for corrosive liquid media. 0% or better. 20160829 Clamp on sensor installation instruction - Duration: Adjusting K Factor in Electronic Turbine Flow Meter. Meters available to Barwon Water and Application. If higher viscosity working fluids are involved, the single-use flow through disposable ultrasonic sensors are the best fit. Cost-Effective Performance That’s Field Tested and Field Proven. Installation Guide. This manual is intended to describe the theory of operation, typical operating characteristics and applications of turbine meters as well as installation specifications, calibration, testing and maintenance procedures, and computations used in the calculations of flow by axial flow. Power requirements:AC/DC battery. The large coverage of high flow rates and high pressures makes it possible to use these Meters where other models might not meet the requirements for large flow duties of Gas. After exploring how each flow meter works the way it does, learn more about which is the best fit for your needs and why. It is one of the most precise and reproducible flow meters accessible for transfer of custody. The flow-meter may be installed in any orientation (vertical, horizontal, etc. The F-1100 Series Flow Meters deliver highly accurate flow data when used in applications with a straight pipe run along enough to establish a fully developed flow profile. Badger Meter’s new Blancett Top Load Turbine Flow Meter was introduced at the Turbomachinery & Pump Symposia in Houston, Texas. Principle of Operation Turbine flow meters consist of a pipe section with a multi-bladed rotor suspended in the fluid stream on a free running bearing, see Figure 3. A minimum of 10 pipe diameters of straight pipe on the inlet is required. The pickoff mountings are oriented with the pickups 90° electrically out of phase. Thanks Mech Plaza aka பட்டறை. Turbine Meter. “Measurement Uncertainty “ Presented by E. In the market for a new regulator? Message here. Verify accuracy after connections are complete. Badger Meter’s new Blancett Top Load Turbine Flow Meter was introduced at the Turbomachinery & Pump Symposia in Houston, Texas. When selecting and sizing Turbine flow meters, the guide listed below can help in ensuring that the right meter is selected and correctly sized for your application: (a) Turbine Flowmeters are sized by volumetric flow rate; however the main factor that affects the meter is viscosity. Use the bracket to secure the Flow Meter. Use a wrench only on wrench flats. Flow Meters, Turbine Flow Meters, Insertion Flow Meters. The single-use sensor contains a frictionless turbine wheel that is extremely responsive to changes in fluid flow moving through it. HP Turbine Installation and Maintenance Guide 1-3 Caution should be exercised to avoid air in the line, sudden flow surges, or excessive flow rates, as these conditions may cause damage to the turbine measuring element. Swirl or non-uniform velocity profiles, such as jetting, at the turbine meter inlet can cause undesirable accuracy performance changes. If any problems with the flow meter arise, consult the Trouble Shooting Guide (Appendix A). Arian FL40 flow computer description. The main advantage of these types of flow meters is their ability to handle high viscous and corrosive fluid, and they typically do not require filtration prior to processing. These highly accurate meters are ideally suited for measurement of natural gas, propane, butane, nitrogen, methane, CO2, CO, helium, ethane, and a variety of other industrial gases including air at both high and low pressures. Custody transfer of gaseous flow measurement follow guidelines set by the international bodies. 0% or better. Turbine Meters (TM) 2”, 3”, 4”, 6”, 8”, 10” Specifications Applications - For use in measurement of potable cold water in residential, commercial and industrial services where flow is in one direction only. Additionally, all brass Venturi valves feature a union tailpiece inlet connection, allowing for quick installation and servicing of system components. API TR 2578 - Flow Conditioner Installation and Effects on Turbine Meters October 1, 2017 - API API MPMS Chapter 5. Flow Meter TR90-PP Ideal for measuring neutral liquids, acids and alkalis and many other non-flammable liquids. Machine Parts of 50 kw hydro generator/water turbine generators Francis Turbine Casing. The following suggestions apply to larger meter vaults or pits: inches and larger with the exception of multi-jet meters, which are between 5/8” and two inches. Principle of Operation Turbine flow meters consist of a pipe section with a multi-bladed rotor suspended in the fluid stream on a free running bearing, see Figure 3. OPERATING ABOVE/BELOW THE RANGE OF THE METER. The pickoff mountings are oriented with the pickups 90° electrically out of phase. Water, natural gas, steam, mineral oil, chemicals are some of the fluids that have to be measured day in, day out. turbine, including the serial number is etched on the meter body. meter installation to minimize the total flow each installation experiences in the changeover flow range. Now those basic principles are all still valid but maybe. They offer a wide flow and application rangeability. The rotation of the rotor is detected by a non-drag Hall-effect sensor. The sensor detects the rotation of the flow meter’s gears and emits a fre-quency signal proportional to flow. 2 Mass flow rate vs volume flow. Turbine meter performance can be adversely affected if debris damages or alters the shape of the. Positive displacement flow meters have long been the technology of choice for applications requiring very precise delivery of high-value liquid product. Turbine flow meters use the mechanical energy of the liquid to rotate a rotor in the flow stream. The flow meter is highly accurate and often used for testing the performance of pumps, engines, valves and other flow meters. Flow measurement is a critical aspect of operations involving pumps, valves and other industrial systems. We are proud that you have selected a Hoffer Turbine Flowmeter, the finest precision turbine flow transducer on the market. developed to standardise the installation of flow meter and raise the quality of water take information by setting guidelines and technical specifications for the selection of and installation of flow meters. Hand tighten only. It is important to note that in 1998 little was known about the USMs installation effects, long-term performance and reliability. 2) by Lee S. Specifically, we provide in-line and insertion turbine meters, variable area (rotameter) and positive displacement meters, MAG/RF pickups, ratemeters,. meter installation to minimize the total flow each installation experiences in the changeover flow range. typical flow meter system installation. Return to Cold Water Meters – Turbine HP Turbine water meters offer some of the widest flow ranges of any turbine meters on the market. Flush the entire system so that it is free of flux, solder, and slag. Electronic in-line turbine meter that may be installed at the end of a hose or plumbed in a fixed pipe installation with the 1 inch NPT Inlet/Outlet. GUIDELINES FOR FLOW MEASUREMENT (PROJECT STANDARDS AND SPECIFICATIONS) Page 2 of 26 Rev: 01 August 2011 SMALL BORE AND INTEGRAL ORIFICE 14 Application 14 Design 14 Materials and Construction 14 Installation 15 TURBINE METERS (LIQUID) 15 Application 15 Design 15 Installation 16 TURBINE METERS (GAS) 16 Application 16 Design 16 Installation 17. All flow through Flow Meter must go to booms only, i. F-13 Inline Turbine Meter ¾" and 1" Example: "F-1210" = Dual turbine, analog output II. Model DH500 turbine flow meter, turbine flowmeter, flow meter turbine adapts to measure the liquid rate and total flowrate of low viscosity. The Q Series Turbine gas meters are heavy duty industrial meters meant for higher flow applications for both indoor and outdoor use. Fluid lines should also be checked and cleared of all debris. The flow-meter may be installed in any orientation (vertical, horizontal, etc. The range of liquid turbine flow meters includes the Daniel Series 1200 and 1500 Liquid Turbine Flow Meters, each of which is designed for specific industry segments. wastewater flow measurement system or technique used measures the total wastewater discharged (described by the NPDES permit, if applicable). Our extensive range of hire products include ultrasonic clamp-on flow meters, mag meters, stainless steel turbines, oval gear flow meters, variable area meters and instrumentation as well as accessories including data-loggers, signal converters and telemetery products. 2) Mount Flow Meter horizontal to the ground. meter installation to minimize the total flow each installation experiences in the changeover flow range. Gas Turbine Flow Meter HLWQ series gas turbine flowmeter is widely used for flow measurement of natural gas, coal gas, liquefied gas and light hydrocarbon gas, etc. Sanitary turbine flow meters are economic and easy to install. The direction is indicated by the ar-row, cast -molded in the turbine. The Gx turbine flow meter is suitable for the measurement of dry gases (inert and flammable), and is designed to operate at line pressures down to 0. Flowmetrix are the leaders in flow meter manufacture and flow measurement in South Africa. Female Thread Turbine Flow Meter; Male Thread Turbine Flow Meter; Tri-Clamp Turbine Flow Meter; Wafer Turbine Flow Meter; turbine flow meter advantages and disadvantages; turbine flow meter installation guidelines manual; Oil Turbine Flow Meter; turbine gas flow meter working principle; Liquid turbine flow meter calibration procedure; Turbine. Operating under the same principle as a Rotary meter, the Turbine Meter is utilized when flow rates are very high. Repeats at high flow. The installation will also ensure that temperature and pressure measurements. The vanes are located (fig. Turbine meters are less accurate than displacement and jet meters at low flow rates, but the measuring element does not occupy or severely restrict the entire path of flow. The newly developed measuring insert with a special construction of the turbine where the water flows through, gua-. Dual counter-rotating axial turbine elements, each with its own rotational sensing system, and an averaging circuit to reduce measurement errors due to swirl and flow profile distortion. Alignment rings are available to align the meter body with flange faces. The installation will ensure, where necessary, appropriate flow conditioning both upstream and downstream of the meter or meters are included. must be completed prior to installation of the Turbo-Meter in line. When meters with flow totalisers attached are located between 0. Turbine Flo eter Model 11 Installation, peration aintenance anual 6 Kimray is an ISO 9001- certified manufacturer. SOLUTIONS (Available to PD/TURBINE METER TECHNOLOGY (INSERT TO GUIDE TO MARKETING TERMINALS). As fluid flows through the turbine meter, it impinges upon turbine blades that are free to rotate about an axis along the center line of the turbine housing. 1 Check the inside of the flow meter for any foreign material Make sure the turbine rotor spins freely prior to installation Also, check fluid lines and remove any debris found 2 Install the flow meter with the flow arrow, etched onto the exterior of the meter body,. In general, downstream straight run requirements for turbine flow meters are around 5-10x the piping diameter. The average velocity multiplied by the cross-sectional flow area equals the volumetric flow rate. Installation of Turbine flowmeter: First check the flow meter is free from foreign materials and the turbine should rotate freely. Turbine gas flow meter consists of turbine flow sensor and display instrument and it is made by us using foreign state-of-the-art technologies, which is an ideal gauge for measuring of liquid flow. Turbine flow meters are generally shipped in one package unless optional hardware or equipment is ordered. FLOW METER PIPING REQUIREMENTS “Diameters” of straight pipe required for various types of fl ow meters Diameter (D) = nominal Pipe Size Example: 13 Diameters of 6" pipe = 78" 13 Diameters of 10" pipe = 130" Beta = (Bore I. Flow Meter, Gas Meter, Fuel Flow Meter manufacturer / supplier in China, offering China Supplier Gas Turbine Flow Meter on Trade Measuring, China Kunke Roots Flow Meter Natural Gas Flowmeter with 1. If the computer display is upside down, remove the four screws, turn the display 180 degrees and reinstall the screws. The F-1100 Series Flow Meters deliver highly accurate flow data when used in applications with a straight pipe run along enough to establish a fully developed flow profile. Installation Hardware Reference Guide for Insertion Turbine Flow Meters Pipe Material Kit Description Items Included With Kit Item # Price Standard flow meter installation kit for 1¼" and larger welded steel pipe 1" full port bronze ball valve 1" brass close nipple 1" weld-on carbon steel branch outlet INSTL1 51. The Q75 Turbine Gas Meters have many different Flow Ranges available over the possible connection sizes. The Hoffer Sanitary Series of turbine flowmeters are designed to meet the 3-A Sanitary Standard No. Body materials PVC, carbon steel, and stainless steel. Some types of velocity flow meters include: turbine flow meters, electromagnetic flow meters, calorimetric flow meters, vortex flow meters, pitot tube flow meters and ultrasonic flow meters. Threaded aluminium body. you may be knowing that flow is directly proportional to square of differential pressure you can use pitot tube or anubar to measure the flow this will definately give clear idea. 5% of the reading. Installation conditions that may adversely impact the accuracy of. If you need help selecting a flow meter give us a call at 1-800-899-0553 and an expert will be glad help you. For over forty-five years Hoffer. Users choosing flow meters to measure the flow of liquids or gases must consider key factors to make the right decision. This manual applies to all Insertion Flow Meters. Turbine Flo eter Model 11 Installation, peration aintenance anual 6 Kimray is an ISO 9001- certified manufacturer. Foxboro is a good fit within the Schneider structure as they are manufacturers of quality process measurement instruments that are intended to function within sophisticated device networks. Dresser meters and instruments products include a comprehensive range of rotary, turbine, and diaphragm meters, metering instrumentation, and test equipment for the global natural gas distribution and transmission industry. Replace the inlet Flo-Guide® and outlet flow. FEATURES Unmatched Price vs. A general rule of thumb is to install a wind turbine on a tower with the bottom of the rotor blades at least 30 feet (9 meters) above any obstacle that is within 300 feet (90 meters) of the tower. As fluid flows through the turbine meter, it impinges upon turbine blades that are free to rotate about an axis along the center line of the turbine housing. Mass flow rate is the ideal measurement value because it is independent of pressure and temperature, although volume flow rate is usually technically more convenient to measure and, therefore, is preferred. The FLOMEC® QS200 Insertion Ultrasonic Flow meter is engineered to provide exceptional accuracy at low flow rates reducing system maintenance and improving system reliability by eliminating false alarms in drip systems caused by inaccurate flow sensors and identifying blocked sprinklers before costly damage can occur. Recommended turbine meter installation requires a minimum. If problems arise with the flow meter and monitor, consult the "Troubleshooting Guide" on page 13. Donation Standard Specifications and Details for Design and Construction -- Table Turbine Meter Guidelines. WARNING: Damage can be caused by striking an emply meter with a high velocity flow stream. As referred to in Attachment I, the Agreement establishes access rights and installation agreements. The gas turbine contains an 18-stage. Analogue Output In order to transduce the measured flow data, an analogue output is available,. Hawk Surface Measurement Solutions. · Select an installation location at which the turbine is fully filled with liquid. Certification of calibration is included with every meter. DANIEL™ SERIES 1500 TURBINE METER 3. Positive Displacement Flow Meters for High Viscosity Fluids; Power Supplies for Turbine & Paddle Wheel Flow Meters; Signal Conditioners; Technical Reference - Turbine and Paddle Wheel Flow Meters; Turbine Flow Meters; Product by Category; Temperature; Pressure, Strain and Force; Flow & Level; pH & Conductivity; Heaters; Data Acquisition; Automation. Up until recently fuel flow meters used mechanical measurement tools such as turbine or positive displacement; today, most fuel flow meters use ultrasonic sensors to communicate flow rate data to computerized receptors. Neptune's High Performance (HP) Turbine water meters provide water utilities with accurate readings at flows from 4 gpm to 8,000 gpm - some of the widest flow ranges of any turbine meters on the market. TB Turbine Flow Meter Instructions The TB are bronze-bodied turbine meters designed for use in pipe sizes 1" to 4". The QuadraTherm® 640i is the most accurate insertion-probe thermal mass flow meter for air / gas mass flow rate measurement on the market today, achieving gas mass flow rate accuracy never before possible, +/- 0. Flow Measurement With ABB's knowledge about flow measurement and management, you have access to over 100 years of flow measurement and control experience to help you save cost and increase profits. 0 TARGET AUDIENCE This is intended for all people installing flow meters as a requirement of a Hawke's Bay Regional. HP Turbine Installation and Maintenance Guide 1-3 Caution should be exercised to avoid air in the line, sudden flow surges, or excessive flow rates, as these conditions may cause damage to the turbine measuring element. 1) Mount Flow Meter in the area of the boom valves per Figure 4. Be prepared to provide this information if you call customer support. Yorkshire Water | YW Wholesale Policy on the installation, repair and replacement of a Non-Household Water Meter/ Version 2 / 14. Insertion Turbine Flow Meter Installation & Adjustment Guide 2161 Logan St. The nacelle tilt and roll movements when the turbine is in operation, affect the lidar measurement height. This widens the application scope from the previous standard which was primarily aimed at hydrocarbon custody transfer applications. Information concerning the volume of available water is very helpful in planning. The product possesses advantages of simple structure, light in weight, high accuracy, good repeatability, short response time, easy installation, etc. The price of the meter technology is one aspect to consider as well as installation and life cycle costs for the total ownership cost (includes factors such as footprint, flow conditioning, […]. ”The flow direction is indicated on the housing by means of an arrow. Read McCrometer's Company Profile Here. This section includes a summary of the causes of problems that tend to occur during flow control. Fiorentini Turbine Meters and removable cartridge assemblies are each supplied with a calibration certificate. 28-03 for measurement of process liquids and can be used where high sanitary standards are required. Turbine meters are less accurate than displacement and jet meters at low flow rates, but the measuring element does not occupy or severely restrict the entire path of flow. This battery (as supplied standard) acts as the primary power for the unit unless DC power or loop power is connected when it then serves as a battery backup for DC/loop power loss. G40 Turbine Quantometer Gas Meter - 2" Part number: 22124. Intermediate and/or Variable Flows (Compound Meters) Applications with peak flow above the maximum operational limits given for positive displacement meters or below the minimum adjusted average daily flows for turbine meters shall. The flow-meter may be installed in any orientation (vertical, horizontal, etc. 0 Accuracy, Precession Vortex Flowmeter for Nature Gas Measurement and so on. The main advantage of these types of flow meters is their ability to handle high viscous and corrosive fluid, and they typically do not require filtration prior to processing. • Due to the laws of physics, for optimum results any flow meter (including turbine flow meters) should be operat- ed as high up in their turndown range as possible. When selecting and sizing Turbine flow meters, the guide listed below can help in ensuring that the right meter is selected and correctly sized for your application: (a) Turbine Flowmeters are sized by volumetric flow rate; however the main factor that affects the meter is viscosity. 2 INSTALLATION Guidelines Installation Illustrations A Install in a horizontal pipe section at a low point before a rising pipeline to ensure meter body remains full. Gas Flow Measurement • Mass flow measurement base on thermal dispersion • A heated body in a flowing gas stream gives off heat to the flowing gas due to the cooling affect of the gas molecules and mass velocity • The amount of heat convected away by the gas is directly related to the mass flow rate • Direct mass flow measurement Slide. The meter translates pulse data from the turbine into calibrated flow units shown on the meter’s readout. 5 Turbine Dop. Most flow meters have pipe fittings for inline installation; the type and size of the fittings varies from meter to meter. 0 TARGET AUDIENCE This is intended for all people installing flow meters as a requirement of a Hawke's Bay Regional. US continental orders over $49 and under 50 pounds may qualify for free ground shipping. Designed to be low-maintenance without moving parts, these flowmeters measure independent of pressure, density, temperature and viscosity across a wide range of diameters – they even meter fluids with entrained solids. Barchard Engineering Ltd. A gas meter is a specialized flow meter, used to measure the volume of fuel gases such as natural gas and liquefied petroleum gas. “Gas Turbine Meter Measurement“ Presented by Wayland Sligh, of Daniel Measurement and Controls, Inc. Turbine meters must operate in a completely filled line at all times. O TURBINE MAGNETIC PICKUP 1 AB. Integral Conditioned Outputs. Insertion-Type Turbine Meter a. Kimray quality assurance process maintains strict controls of materials and the certification of parts used in Kimray electronic level switch. The flow meter is ideal for measuring flow rates in cooling circuits, HVAC systems and batching operations. KLWQD series gas turbine flowmeter is a kind of velocity flowmeter used for accurately measuring the flow rate of gas medium, It has the advantages of high measuring precision, good repeatability, wide measuring range, light structure, simple installation, convenient maintenance, small pressure loss, long service life and convenient operation. The FLOMEC® EGM Series Oval Gear meters provide exceptional accuracy in an economical package. cubic meters liters user-defined TURBINE MAGNETIC PICKUP MAY BE 991 OR 458 SERIES NUFLO FLOWMETER OR ANY APPROVED DEVICE WITH THE FOLLOWING MAXIMUM ENTITY PARAMATERS: Vmax = 6. The standard provides installation guidelines for various turbine meter body designs (in-line, in-line. The design of flow measurement systems involves a wide variety of multidisciplinary activities including modelling the flow sensor. Positive Displacement Flow Meters for High Viscosity Fluids; Power Supplies for Turbine & Paddle Wheel Flow Meters; Signal Conditioners; Technical Reference - Turbine and Paddle Wheel Flow Meters; Turbine Flow Meters; Product by Category; Temperature; Pressure, Strain and Force; Flow & Level; pH & Conductivity; Heaters; Data Acquisition; Automation. MTX Turbine Flowmeter Installation & Operation Manual. Turbine Meters (TM) 2", 3", 4", 6", 8", 10" Specifications Applications - For use in measurement of potable cold water in residential, commercial and industrial services where flow is in one direction only. For the lowest uncertainty of measurement, positive displacement meters are generally the best option. A variable area flow meter, or rotameter, has a tapered tube and a float that indicates readings on an analog scale. Positive Displacement Flow Meters for High Viscosity Fluids; Power Supplies for Turbine & Paddle Wheel Flow Meters; Signal Conditioners; Technical Reference - Turbine and Paddle Wheel Flow Meters; Turbine Flow Meters; Product by Category; Temperature; Pressure, Strain and Force; Flow & Level; pH & Conductivity; Heaters; Data Acquisition; Automation. 74 MB Nutating Disc Meter Installation & Operation. The weatherproof, UV resistant, large, dual line display allows for more information, making it easier to read and simpler to program. Selection Guide Top Load Turbine Flow Meter at. Turbine Flow Meters are easy to maintain. This section includes a summary of the causes of problems that tend to occur during flow control. Page 1 FLOW AND ENERGY MEASUREMENT SYSTEM-10 BTU METER Installation and Operation Guide For Software Version DM 1. cl 1 Theory overview of flow measurement using differential pressure devices based on ISO-5167 standard. Hands-on knowledge of Orifice flow meter, Turbine flow meter, Ultrasonic flow meter & Coriolis flow meter. The DF25 uses the well-established Differential Pressure (DP) measurement method. (a) This Standard applies to: (1) axial full-flow turbine meters with mechanical and/or electrical outputs whose rotating member is driven by a compressible fluid; (2) the measurement of gas by a turbine meter; the meter's construction, installation, operation, performance characteristics, data computation and presentation, calibration, field checking, and other related considerations of the. A minimum of 10 pipe diameters of straight pipe on the inlet is required. Turbine Meters (TM) 2", 3", 4", 6", 8", 10" Specifications Applications - For use in measurement of potable cold water in residential, commercial and industrial services where flow is in one direction only. Thus, causing the turbine meter to give inaccurate readings. Be sure the rotor is free to spin before placing the meter in the flow line. ) Bore is the smallest diameter of an orifi ce or nozzle Up = Upstream Diameters Down = Downstream Diameters. Flow Measurement Devices Increasing utilization and the value of water makes the understanding of water measuring techniques important and necessary. 8 Differential Devices with a Flow Measurement Mechanism in the Bypass 167 8. High-quality jewel bearings and ceramic shafts are used in the standard version. Also mentioned are common problems and considerations regarding field testing. Our turbine flow meter includes flange,thread,flange card and insertion type,size from DN4-DN200,accuracy can be up to 0. We have the UK’s largest fleet of flow meters to hire. FLOW METER PIPING REQUIREMENTS “Diameters” of straight pipe required for various types of fl ow meters Diameter (D) = nominal Pipe Size Example: 13 Diameters of 6" pipe = 78" 13 Diameters of 10" pipe = 130" Beta = (Bore I. We are committed to developing innovative, high-quality, precision flow meters for the most demanding liquid, steam and gas flow measurement for our worldwide customers. Electronic in-line turbine meter that may be installed at the end of a hose or plumbed in a fixed pipe installation with the 1 inch NPT Inlet/Outlet. 2 x Qmax Qn Max Continuous Flow + 2% Qt Transitional Flow + 2% Qmin Minimum Flow + 5%. Instead, good flow data acquisition comes after years of experience carefully. It provides an overview of methods used in a variety of situations from calibrations in standards laboratories to those in the field, including flow meter verification in a non-laboratory situation. The DF25 is an insertion Averaging Pitot tube which is install across the internal diameter of the pipe. This Guide gives recommendations on the design, installation, operation and maintenance of turbine metering systems used for liquid measurement. General- All cold Turbine water meters conform to the AWWA C701 Cold Water Meters - Turbine Type, for. High-quality jewel bearings and ceramic shafts are used in the standard version. FLOW AND ENERGY MEASUREMENT TURBINE FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo FL 33773 • USA • Tel +1 (727) 447-6140 • Fax +1 (727) 442-5699 0721-6 / 13518 www. Alignment rings are available to align the meter body with flange faces. Installation hardware kits are listed immediately after insertion type flow meters. They measure total flow in gallons. Versatile and easy to use, the EDM's modular design allows KOBOLD. The QuadraTherm® 640i is the most accurate insertion-probe thermal mass flow meter for air / gas mass flow rate measurement on the market today, achieving gas mass flow rate accuracy never before possible, +/- 0. HP Turbine Installation and Maintenance Guide 1-3 Caution should be exercised to avoid air in the line, sudden flow surges, or excessive flow rates, as these conditions may cause damage to the turbine measuring element. For use with serial numbers 115692 and later. 6 Dall Tubes and Devices that Approximate to Venturis and Nozzles 163 8. 1) packs a full spectrum of gas and liquid measurement functionality, high-speed performance, and log archive and retrieval capabilities in an easy-to-use, explosion-proof totalizer. It is a very accurate meter and can be used for clean liquids and viscous liquids up to 100 centistokes. 1, What is a turbine flow meters? How and when is it used ? A turbine flow meter is a liquid/gas measurement device. As a distributor for Itron, occasionally we’re asked, “How do you install a natural gas pressure regulator?” The following provides installation and start-up instructions for Itron’s B-series regulators (Models B42, B57, B58, B31, B34S, B34, B38, B35, B36, and B56). An equally cost-effective alternative is the Vortex flow meter, which offers a variety of applications with multi-parameter measurement capability for liquids, gases and steam. Flange Connection Use a gasket between the meter. O TURBINE MAGNETIC PICKUP 1 AB. It is a very accurate meter and can be used for clean liquids and viscous liquids up to 100 centistokes. 0 INSTALLATION 3. For over forty-five years Hoffer. Turbine and current meters, including electronic flowmeters, are used when flows are large, minimum flows are usually above 10 or 12 percent of maximum rating, and the low‑pressure loss at high flows is valuable. Before Operation Before putting the HP Turbine meter in service follow these steps: 1. Neptune’s UL/FM approved fire service turbine meters offer some of the widest flow ranges available in a fire service meter and are designed to maintain pinpoint accuracy without compromising water flow. Pipe/End Connection Installation A straight section of pipe with required end connections should be installed on either side of the intended meter’s location prior to installing the meter. C Do not install in a horizontal pipe. There are significant differences between meter designs, with each type of device having its own pros and cons. The effect of the velocity profile of the flow stream on orifice, ultrasonic, and turbine flow meters is discussed next. Liquid examples: Glycol, ferric(III)chloride, hydrochloric acid, phosphoric acid, etc.